100-1723-PK-100 MetPak II Weather Station View PDF Catalog Page

MetPak II
MetPak™ II Weather Station

The MetPak™ II, manufactured by Gill Instruments Ltd, is an enhanced multi-sensor weather station that measures a wide range of weather parameters, including: wind speed and direction; air temperature; relative humidity; barometric pressure and dew point.

Gill ultrasonic technology, as used in the proven WindSonic instrument, measures wind speed and direction. Temperature and humidity are measured using industry standard probes housed in a naturally aspirated radiation shield. Barometric pressure is measured within a vented enclosure. A serial data output is provided to interface with industry standard data loggers.

The MetPak™ II weather station can be supplied with digital SDI-12, RS232, and RS422 outputs. Low power consumption enables this weather station instrument to be used in remote locations where power is at a premium. An electrical junction box is fitted to the mounting bracket allowing convenient termination of all electrical cables.

The MetPak™ II weather station is provided with Gill MetView software, which allows for complete weather monitoring via one easy-to-navigate screen.

Specifications

Wind Speed and Direction
Parameters: Wind speed & direction or U & V (Vectors)
Units of measure: m/s, knots, mph, kph, ft/min

Wind Speed
Range: 0-60m/s (134 mph)
Accuracy: ±2% @12m/s
Resolution: 0.01m/s (0.02 mph)
Threshold: 0.01m/s (0.02mph)

Wind Direction
Range: 0 to 359° - No dead band
Accuracy: ±3° @12m/s
Resolution: 1°

Air Temperature
Sensor: PT100 1/3 Class B
Range: -35°C to +70°C
Accuracy: ±0.1°C
Resolution: 0.1°C (0.1°F)
Units of measure: °C or °F
Radiation shield: 6-plate naturally aspirated

Relative Humidity
Range: 0-100% RH
Accuracy: 0.8% @23°C
Resolution: 0.1% RH
Units of measure: % RH

Barometric Pressure
Range: 600-1100hPa
Accuracy: ±0.5 mbar (hPa)
Resolution: 0.1 mbar (hPa)
Units of measure: hPa, mbar, mmHg, InsHg
Compensated for temperature dependency -20°C to +70°C

Dew Point
Resolution: 0.1°C (0.1°F)
Units of measure: °C or °F
Accuracy: ±0.15°C (23°C ambient temp @20°C dew point)

Power Supply
RS232, RS422
   Input voltage: 5 V to 30 V
   Current: 36mA (Output 1 second) @12 V
SDI-12
   Input voltage: 12 V nominal (9.6-16 V)
   Current: < 36mA

Outputs
Digital outputs: RS232, RS422 or SDI-12
Baud rates: 9600-57600 (ASCII) or 1200 (SDI-12)
Protocols: ASCII or SDI-12 V1.3
Data output: 1s, 2s, 4s or polled mode

Environmental
Protection class: IP65
EMC: EN 61326
Operating temperature: -35°C to +70°C
Storage temperature: -40°C to +80°C
Operating humidity: 0% to 100% humidity

Mechanical
External construction: UV stabilised white thermoplastic
Fittings: Gloss white painted aluminium mounting bracket (with moulded plastic V-block and stainless steel U-bolt), which allows attachment to a vertical pipe of any diameter between 25mm and 50mm
Weight: 1.1kg (including bracket)

Software
MetView: Free software providing the means for configuring the Metpak II and reading output data

Ordering Information

100-1723-PK-100 MetPak™ II Weather Station (WS/WD/T/RH/BP)
100-1723-10-051 USB Configuration Cable, 1.8m
100-1723-10-053 Power & Communication Cable, 15m

Go to...
Weather Stations
Main Table of Contents
Top of Page