195-WS-16 Data Logger 
![]() ![]() |
![]() |
| 195-WS-16D Data Logger in Desktop Enclosure | 195-WS-16N Data Logger in NEMA Enclosure |
The 195-WS-16 Data Logger is designed specifically for collecting meteorological data. It has a versatile processor that can be used in systems from portable stations to networks. It is a complete package with sensor interfaces, data processing and logging, communications interfaces, and software for display, reporting, and data retrieval via a standard RS232 cable. Two independent user programmable alarms are supplied.
The 195-WS-16 supports a large variety of sensors. A 30-pin terminal strip is supplied for directly connecting analog and digital sensors without the need for external signal conditioning components or special programming. Sensor data are sampled every 2 seconds and logged at intervals selected by the user. The averaging period and logging interval can also be changed by the user. Each data record is logged with time and date. Data memory is backed with a 7 year lithium battery. Wind data are calculated in vector and scalar forms. The internal microprocessor determines weather parameters, generates standard reports, handles communications, and performs self-diagnostic tests.
The 195-WS-16 is typically powered by 12 Vdc. Operating current is less than 55 mA at 12 Vdc. An optional low power version is available for remote battery operated stations.
The 195-WS-16 is a completely self-contained data collector and processor for automatic stations. It is designed to withstand exposure to severe outdoor weather conditions. All components are contained in the rugged NEMA-4X weatherproof fiberglass enclosure. Internal circuit boards have surface mounted components for improved reliability. Three stages of lightning and transient protection are included on all signal and power connections. A desktop version is available for indoor use.
Data can be viewed using Windows HyperTerminal or other terminal programs such as Procomm. A one page real-time text display or an ASCII row and column format may be selected. A menu is provided for setting the date and time, alarms, logging interval, etc. Optional graphical display software is available for viewing real-time and historical data charts and graphs.
Specifications
Analog Inputs
Number of channels: 7 voltage inputs, 1 input for PT100, 2 inputs for 10K thermistor
Input ranges: 100 mV, 1.0 V, 2.0 V, 5.0 V
Accuracy: 0.1% F.S., 5 V range (-40 to 60 °C)
Sample rate: 1 KHz maximum
Resolution: 12 bit
Digital Inputs/Outputs
Frequency inputs: 3 counters, 16-bit each independent of processor
Maximum count rate: 10 KHz
Input modes: 2 high speed inputs for sine wave or square wave anemometers, 1 input for contact closure rain gauges
Alarm outputs: 2 open collector @ 2 A max for high or low threshold events
Serial Channels
RS232C port: 1 port with hardware and software handshaking, baud rates 110 bps to 56 Kbps, 9 pin d-sub connector
Processor Functions
Configuration: Stored in non-volatile EEPROM
Standard data memory: 128 KB SRAM with battery backup
Optional data memory: 256 KB, 512 KB
Calendar clock: Date, time, leap year, accuracy ±30 sec/month
Backup battery: For memory and clock, 7 year life
Power Requirements
Input voltage: +7 to 40 Vdc
Operating current: < 55 mA @ 12 Vdc
Optional sleep mode: .5 mA @ 12 Vdc
Input protection: Fuse, surge protection, reverse polarity, and over-voltage
Supply sources: Battery, solar power, unregulated DC
Environmental Characteristics
Operating temperature: -40 to 60 °C
Humidity: 0-90% RH non-condensing
Construction
Circuit boards: Approx 90% surface mounted components, internal power and ground planes, and built-in EMI and ESD protection
Lightning protection: Minimum 2 stages of protection devices on all signal and power lines when connected to an external earth ground. Includes MOVs on wind sensor input.
Connections: User interface PCB 30-pin screw terminal, ground lug
NEMA-4X enclosure: 13" x 11" x 6" fiberglass
Desktop enclosure: 7" x 7" x 3-3/4" aluminum
Ordering Information
195-WS-16D Data Logger Desktop Enclosure, with 6' serial cable, no power supply (order below)
195-WS-16N Data Logger in NEMA-4X Fiberglass Enclosure, with 25' serial cable, no power supply (order below)
195-WS-16A Audible Alarm Option
195-WS-16HHD Hand Held PC for local display of real time data
195-WS-16LP Optional Low Power Feature
195-WS-16M Telephone Modem
110-WS-16MDC Telephone Modem, 12 Vdc
195-WS-16M2 Optional Memory Expansion to 256KB
195-WS-16M5 Optional Memory Expansion to 512KB
195-WS-16P AC Power Supply, for desktop enclosure, 120V
195-WS-16PE AC Power Supply, for desktop enclosure, 220V
195-WS-16SML Display Software
195-WS-16SMM Met Manager Software
195-WS-16STR Graphical Display Software
195-WS-16STR-H HTML Opption
110-WS-16CAO CAMEO/ALOHA Output Format
320-600-A Solar Panel Battery Charger, 10W
395-A Tower or Mast Mount Hardware Assy
395-C 12Vdc Power Supply/Battery Charger Assy, for NEMA enclosure, 115Vac
395-D 12Vdc Power Supply/Battery Charger Assy, for NEMA enclosure, 220Vac
395-E Sunshield Assy
395-H 7AH Battery Assy
Go to...
Data Acquisition
Main Table of Contents
Top of Page