260-2102 Rain Logger 
![]() |
![]() |
| Rain Logger in Waterproof Case | Software Screenshot |
The 260-2102 Rain Logger is an event data logger that connects to standard tipping bucket rain gauges to provide detailed rainfall history. The data can be useful in a wide range of fields such as agriculture, forestry, hydrology, and climatology.
This compact unit comes in a weatherproof case. It records the date and time of each bucket tip, along with the accumulated totals. Data is stored in nonvolatile EEPROM memory that retains collected data even if the battery fails. Direct USB connectivity provides fast data readout.
The 2102 runs for up to 1 year on a user-replaceable battery.
The 43,000 tip/event capacity can record up to 430" of rainfall between readouts at 0.01" per tip. A red light blinks every two seconds when the unit is logging. For start up and readout, the 260-2102 connects easily to your PC using the 195-BHW-LITE Software Starter Kit. The starter kit includes software CD, a USB interface cable, and a manual. The cable connects to an available USB port on your PC.
Analysis Functions for Event Logger Data
- Number of events
- Cumulative event totals
- Print preview
Other Features
- Offload logged data or check status while logging
- Print graphs
- Print preview
Specifications
Event type: Relay contact opening (rain gauge tip)
Event resolution: 0.5 seconds
Minimum event duration: 20 microseconds
Operating temperature: -4° to +158° F (-20° to +70° C)
Timekeeping accuracy: ±1 minute per week at 20° C
Capacity: 43,000 events
Battery: CR-2032 lithium
Logger case (waterproof): Clear ABS, 2.7" x 4.3" x 1.3"
Minimum System Requirements for Windows:
Microsoft Windows XP Professional or Home Edition, Windows 2000 Professional, Windows Vista, or Windows 7
Sun Java Runtime Environment (JRE) version 1.4.2 or greater (included on the installation CD)
256 MB System RAM (512 MB recommended)
USB Port
800 x 600 (minimum) Display Resolution, 256 Colors (1024 x 768 or greater recommended)
Minimum System Requirements for Mac:
Mac OS X versions 10.3.9 or 10.4.x
Java Runtime Environment (JRE) version 1.4.2 or 1.5
256 MB System RAM (512 MB recommended)
7 MB Free Disk Space
USB Port required for supported USB devices, either directly on PC or via ethernet
1024 x 768 Display Resolution (minimum)