Analog Look-Up Table

Use this table to convert your sensor's analog current (0-1mA or 4-20mA) or voltage (0-1V or 0-5V) output to engineering units. Includes wind speed (0-100 miles per hour), wind direction (0-360 degrees), temperature (0-128 degrees), and barometric pressure (millibars and inches of mercury).

mA
0-1
mA
4-20
VOLTS
0-1
VOLTS
0-5
MPH
0-100
DIR
0-360
TEMP
0-128°
BP
950-1050 mb
BP
InHg
0.000004.00.000000.0000.0000.00095028.05
0.031254.50.031250.1563.12511.25495328.15
0.062505.00.062500.3136.25022.50895628.24
0.093755.50.093750.4699.37533.751295928.33
0.125006.00.125000.62512.50045.001696328.42
0.156256.50.156250.78115.62556.252096628.51
0.187507.00.187500.93818.75067.502496928.61
0.218757.50.218751.09421.87578.752897228.70
0.250008.00.250001.25025.00090.003297528.79
0.281258.50.281251.40628.125101.253697828.88
0.312509.00.312501.56331.250112.504098128.98
0.343759.50.343751.71934.375123.754498429.07
0.3750010.00.375001.87537.500135.004898829.16
0.4062510.50.406252.03140.625146.255299129.25
0.4375011.00.437502.18843.750157.505699429.35
0.4687511.50.468752.34446.875168.756099729.44
0.5000012.00.500002.50050.000180.0064100029.53
0.5312512.50.531252.65653.125191.2568100329.62
0.5625013.00.562502.81356.250202.5072100629.71
0.5937513.50.593752.96959.375213.7576100929.81
0.6250014.00.625003.12562.500225.0080101329.90
0.6562514.50.656253.28165.625236.2584101629.99
0.6875015.00.687503.43868.750247.5088101930.08
0.7187515.50.718753.59471.875258.7592102230.18
0.7500016.00.750003.75075.000270.0096102530.27
0.7812516.50.781253.90678.125281.25100102830.36
0.8125017.00.812504.06381.250292.50104103130.45
0.8437517.50.843754.21984.375303.75108103430.55
0.8750018.00.875004.37587.500315.00112103830.64
0.9062518.50.906254.53190.625326.25116104130.73
0.9375019.00.937504.68893.750337.50120104430.82
0.9687519.50.968754.84496.875348.75124104730.91
1.0000020.01.000005.000100.000360.00128105031.01